Open Access

Table 1.

Rigidity of supports of power unit

Name of flexible element Designation Rigidity, kN/m
Factory‐supplied support, new F0 570
Factory‐supplied support, with average wear value F1 380
Factory‐supplied support, worn out F2 320
Rigid spring RS 740
Semi‐rigid spring SRS 250
Flexible spring FS 150