Issue |
BIO Web Conf.
Volume 55, 2022
5th International Conference on Frontiers of Biological Sciences and Engineering (FBSE 2022)
|
|
---|---|---|
Article Number | 01001 | |
Number of page(s) | 4 | |
DOI | https://doi.org/10.1051/bioconf/20225501001 | |
Published online | 21 November 2022 |
Dual-acceptor alloy model delivers high detection performance of organic NIR detectors for real-time arterial pulse monitoring
School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China, No.2006, Xiyuan Ave, West Hi-Tech Zone, Chengdu 610054, China
* Corresponding author: silutao@uestc.edu.cn.
Near-infrared organic photodetectors (NIR-OPDs) have significant potential in the fields of human sign monitoring, industrial defect detection, and military. We propose a method to construct high-performance NIR-OPDs by introducing narrow-band acceptor materials with very similar structures in bulk heterojunctions (BHJs) so that they form an alloy model during the film formation process, which in turn promotes the generation and dissociation of photogenerated excitons to achieve high-performance NIR detectors. Here, we choose the narrow-band materials IEICO-4F and IEICO-4Cl as dual-acceptors and PTB7-Th as the donor to construct NIR-OPDs. Benefiting from the alloy model formation, the dark current of the device is significantly suppressed compared with the binary control, while the photocurrent of the device is enhanced. The optimized NIR-OPD achieved a detectivity of more than 2.6×1012 Jones at -0.1V bias. With the optimized device performance, we can clearly monitor the human arterial pulse information, and the phases of the cardiac cycle of the heart can be accurately identified. This work demonstrates a new method for constructing highperformance NIR-OPDs and shows great potential for contactless human arterial pulse monitoring.
© The Authors, published by EDP Sciences, 2022
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.