Investigation of Corrosion Resistance in Stainless Steel 316L Alloy of Energy Separator by Electroless Plating (Ni-Zn-P)
Department of Matallurigical, Faculty of Material Engineering, University of Babylon, Hilla, Iraq
* Corresponding author: Hassanmm977@gmail.com
The corrosion and hardness resistance of Ni-P coating is well recognized. By adding Zn, the electrochemical and mechanical properties of these coatings can be improved. In the coating procedure, two distinct periods of 1-hour and 2-hours are used. To improve the surface qualities of coating specimens, heat treatment at 400oC for one hour is performed. X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy-dispersive analysis (EDS) were used to analyze the deposits. The hardness values of the coated heat-treated samples exceeded 900HV when compared to the bare and as-plated samples. The Tafel extrapolation test is used to determine the voltage and corrosion current in a 3.5% NaCl solution in order to calculate the corrosion rate. Corrosion rates are reduced from 1.81 mpy in bare specimens to 0.0642 mpy in heat treated plated specimens.
© The Authors, published by EDP Sciences, 2023
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.