Issue |
BIO Web Conf.
Volume 97, 2024
Fifth International Scientific Conference of Alkafeel University (ISCKU 2024)
|
|
---|---|---|
Article Number | 00018 | |
Number of page(s) | 10 | |
DOI | https://doi.org/10.1051/bioconf/20249700018 | |
Published online | 05 April 2024 |
Seismic Evaluation of Retrofitting Technique Using Bracing Systems for Steel Multi-Story Building
1 MSc student at Dep. of Civil Eng., Faculty of Eng., University of Kufa, Iraq
2 Assistant Prof. at Dep. of Civil Eng., Faculty of Eng., University of Kufa, Iraq
* Corresponding author: zainabq.alshmareiy@student.uokufa.edu.iq
A bracing system is the one of effective retrofitting methods for existing high buildings to support the lateral loads. Structural bracings increase the stiffness and stability of the building and the energy dissipation capacity. In this research, the numerical study of retrofitting a multi-story steel building near Imam Ali Holy Shrine in Najaf, Iraq has been conducted. The retrofitting mechanism includes a test of four different bracing systems such as X-bracing, V-bracing, Diagonal-bracing and IV-bracing located in the x and y-axis of the model. The seismic analysis using the elastic response spectrum method was performed for two types of earthquakes, weak and strong. The comparison among different parameters is discussed such as maximum lateral displacement, story drift ratio and base shear values. The seismic load was applied in two axes of the building model simultaneously and the results of the parameters in the x and y-axis were extracted. The results show that the retrofitting using four bracing system types increases the capacity of energy dissipation of the existing building model to seismic load by reducing the maximum lateral displacement in the x-axis by 55%, 44%, 41%, and 30% for X, IV, V and Diagonal-bracing, respectively. However, the X-bracing has a significant increase of the shear base value of the model by 39% and 49% in the x and y-axis, respectively, which means cost-effective compared with the other bracing types. Therefore, the IV-bracing type has an appropriate effect on the strength of the building against seismic load with reasonable cost-effectiveness.
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.