Optimization of immunoturbidimetric assay system enhanced by β2-microglobulin latex
College of Life Science and Technology, Changchun University of Science and Technology, Editorial Department, Changchun, China
* Corresponding author: zhanghao@cust.edu.cn
a 874143077@qq.com
In this study, three-factor and three-level orthogonal experiment was used to optimize the detection system of clinical renal function marker β2-microglobulin latex enhanced immune turbidity, so as to prepare a detection system with a wider linear range, solve the false negative problem in clinical detection of high-concentration samples, and improve the detection accuracy. Based on latex enhanced immunoturbidimetry, automatic biochemical analyzer was used to establish the linear relationship between the β2-microglobulin standard with different concentrations and the absorbance change value of 546 nm, and optimize the antibody source, latex microsphere particle size, activator concentration, sealer concentration and buffer system in the β2-microglobulin detection system. The linear range and accuracy of the optimized detection system were evaluated. After optimization, the optimal detection system was obtained, and its detection linear range was 0.2-30 mg/L, which reached the upper limit of the reference range of β2-microglobulin in normal population by 10 times, and the accuracy was in line with clinical standards, which solved the false negative problem of high-concentration samples in clinical testing, eliminated the repeated dilution process of high-concentration samples, simplified the detection steps, and improved the detection accuracy.
© The Authors, published by EDP Sciences, 2024
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.