Results of coding of investigated factors.

Factors and units of measurement The usual sign The encoded sign Interval of varying Levels of varying
usual encoded
Uppers(+1) Zero (0) Lower (-1) upper(+1) Zero (0) Lower (-1)
Turn pitch of auger shaft(h), mm X1 x1 2 24 22 20 +1 0 -1
Area of openings for oil cake withdrawal (s), mm2 X2 X2 20 129 109 89 +1 0 -1
Rotation frequency of auger press, (n), min.-1 X3 x3 30 75 45 15 +1 0 -1