Evaluation of internal exposure in French nuclear power plants based on whole body counting
1
CHU Rouen, 76000 Rouen, France
2
EDF CNPE du Blayais, BP 27, 33820 Saint Ciers sur Gironde, France
3
EDF CNPE de Paluel, BP 48, 76450 Cany Barville, France
* Corresponding author : matsailly@icloud.com
Key words: Occupational medicine / radiation protection / nuclear power plant / internal contamination / whole body measurements / committed effective dose
Introduction
At EDF, dose assessments for internal contamination were so far mainly done by biologists using in vitro measurements. Several factors lead to change this practice: French regulations which attribute this assessment to occupational physicians [1], accreditation of whole body measurements which legitimates the use of this type of analysis and the development of Cador, a home-made Excel file [2] which allows to easily perform the assessment. The objective of this work was to estimate the interest of whole body measurements for internal contaminations.
Material and method
An analysis of 149 cases of internal contamination which occurred in French nuclear power plants between 2008 and 2015 was conducted. More than one thousand whole body counting spectrums were treated with double-checking. The analysis was led by the last version of Cador using the French Recommendation of HAS [3] and the Chi-squared test provided by European IDEAS guidelines [4].
Most of the contaminations were situated between 0.1 mSv and 1 mSv. This level corresponds to the intermediate level of the French Recommendations of Good Practice and to the level 1 of the IDEAS guidelines. For this level, an estimation based on a single type of analysis is considered sufficient. In this respect, the assessment might be done with whole body measurements only.
In the Recommendations of Good Practice (RGP) the goodness of fit is considered acceptable if there is no more than a factor 3 between the various estimates of intake. The uncertainties are not taken into account. In the IDEAS guidelines, the goodness of fit between the measures and the model is assessed against a Chi-squared test. This method requires knowing the uncertainties of measures. IDEAS guidelines provide values of geometric standard deviation, so called Scattering factors, for various analyses. For whole body measurements of high energy radiation, the Scattering Factor is 1.2.
The first stage refers to RGP method and consists in looking at the gap between the various estimates. The second stage refers to IDEAS method with the Chi-squared test. A coloured rectangle summarizes the results of both methods. The rectangle is green, orange or red depending on whether the fit is good with respectively both methods, any of them or none of them.
Results
30 cases could not be analysed because of an insufficient number of whole body measures. Among 119 remaining cases, 21 cases corresponded to an inhalation model of hot particles where the assessment of activity needed another method [5]. For 32 cases, the activity was too low or the number of measures was insufficient.
For the 66 remaining cases, we were able to exactly identify an incorporation model described by ICRP. RGP and Chi-squared tests were valid in 79% of cases and RGP alone in remaining 21%. The identified models and AMAD observed are shown in table 1.
models identified by RGP and chi-squared test
In an isolated way or not, we found Cobalt 58 in 55% of the cases, Cobalt 60 in 48% of the cases and Argent 110m in 26% of the cases. We also observed Caesium 137, Antimony 124, Zirconium-Niobium 95, Chromium 51 and Manganese 54.
Except the cases of inhalation of a hot particle, the evaluation of the incorporated activity by whole body measurements was comparable to faeces analysis in half of cases. In the other half, the estimated activity from faecal examinations was lower than activity estimated by the whole-body measures.
Conclusion
Finally, 34 cases resulted in a committed effective dose superior to 0,1mSv but lower than 0.5mSv. The whole-body measurements allowed the dose assessment if the time of counting and the number of measure are sufficient.
References
- JORF n°0181 du 6 août 2013 page 13401 texte n° 34. Arrêté du 17 juillet 2013relatif à la carte de suivi médical et au suivi dosimétrique des travailleurs exposés auxrayonnements ionisants, https://www.legifrance.gouv.fr/jo_pdf.do?id=JORFTEXT000027806111 [Google Scholar]
- Landry B, Un outil de calcul de la dose efficace engagée, 2018 Radioprotection 53(1) : 33-44 [Google Scholar]
- Recommandations de Bonne Pratique. Surveillance médico-professionnelle de l’expositioninterne aux radionucléides en Installations Nucléaires de Base, juillet 2011, www.chu-rouen.fr/sfmt/pages/Recommandations.php [Google Scholar]
- Castellani CM, Marsh JW, Hurtgen C, Blanchardon E, Berard P, Giussani A, Lopez MA.IDEAS Guidelines (Version 2) for the Estimation of Comitted Doses from IncorporationMonitoring Data. EURADOS, 2013. Braunschweig, March 2013, http://www.eurados.org/~/media/Files/Eurados/documents/EURADOS Report 2013-01online version.pdf [Google Scholar]
- Sailly M, Lecouteulx I, Rollin L. Evaluation de l’activité d’une particule chaude radioactiveincorporée chez un travailleur du nucléaire. 2018 [Google Scholar]
- Sailly M, Etude de la cinétique anthropogammamétrique après contamination interne parradionucléides émetteurs gamma en installation nucléaire de base, doctoral thesis to bepublished. [Google Scholar]
© The Authors, published by EDP Sciences, 2019
This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
All Tables
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.