Open Access
Issue
BIO Web Conf.
Volume 237, 2026
2026 8th International Conference on Biotechnology and Biomedicine (ICBB 2026)
Article Number 03001
Number of page(s) 6
Section Biomaterials, Medical Devices and Biomedical Engineering
DOI https://doi.org/10.1051/bioconf/202623703001
Published online 10 June 2026
  • Smirnova, D.V. and N.N. Ugarova, Firefly luciferase‐based fusion proteins and their Mensah GA, Fuster V, Murray CJL, Roth GA; Global Burden of Cardiovascular Diseases and Risks Collaboration. (2023). Global burden of cardiovascular diseases and risks, 1990-2022. Journal of the American College of Cardiology, 82(25), 2350–2473. https://doi.org/10.1016/j.jacc.2023.11.007 [Google Scholar]
  • Gross BA, Frerichs KU. Stent usage in the treatment of intracranial aneurysms: past, present and future. J Neurol Neurosurg Psychiatry. 2013 Mar;84(3):244–53. doi: 10.1136/jnnp-2011-302007. Epub 2012 Nov 8. PMID: 23138770. [Google Scholar]
  • Sousa, J. E., Costa, M. A., Abizaid, A. C., Rensing, B. J., Abizaid, A. S., Tanajura, L. F., Kozuma, K., Van Langenhove, G., Sousa, A. G., Falotico, R., Jaeger, J., Popma, J. J., & Serruys, P. W. (2001). Sustained suppression of neointimal proliferation by sirolimus-eluting stents: One-year angiographic and intravascular ultrasound follow-up. Circulation, 104(17), 2007–2011. https://doi.org/10.1161/hc4201.098056 [Google Scholar]
  • Walsh, S. J., & Hanratty, C. G. (2014). Clinical impact of stent design: evolution from stainless steel to cobalt–chromium platforms. Radcliffe Cardiology Review, PMC5808536. [Google Scholar]
  • Boston Scientific. (2016, July). WALLSTENT™ Endoprosthesis. Boston Scientific Corporation. Retrieved from https://www.bostonscientific.com/en‑EU/products/stents‑vascular/wallstent‑endoprosthesis.html [Google Scholar]
  • Liu, L.-L., Qin, J., Zeng, C.-H., Du, R.-J., Pan, T., Ji, J.-J., Lu, L.-G., Chen, L., Liu, D.-F., Yang, J., He, S.-C., Zhu, H.-D., & Teng, G.-J. (2022). Biodegradable PTX-PLGA-coated magnesium stent for benign esophageal stricture: An experimental study. Acta Biomaterialia, 146, 495–505. https://doi.org/10.1016/j.actbio.2022.04.038 [Google Scholar]
  • Zhou, C., Li, H.-F., Yin, Y.-X., Shi, Z.-Z., Li, T., Feng, X.-Y., Zhang, J.-W., Song, C.-X., Cui, X.-S., Xu, K.-L., Zhao, Y.-W., Hou, W.-B., Lu, S.-T., Liu, G., Li, M.-Q., Ma, J.-Y., Toft, E., Volinsky, A. A., Wan, M., Yao, X.-J., Wang, C.-B., Yao, K., Xu, S.-K., Lu, H., Chang, S.-F., Ge, J.-B., Wang, L.-N., & Zhang, H.-J. (2019). Long-term in vivo study of biodegradable Zn-Cu stent: A two-year implantation evaluation in porcine coronary artery. Acta Biomaterialia, 97, 657–670. https://doi.org/10.1016/j.actbio.2019.08.012 [Google Scholar]
  • Song, L., Ran, X., Yan, X., Yan, W., Wang, Q., Yin, T., Zhou, J. G., Hu, T., & Wang, G. (2019). Corrosion behavior and biocompatibility evaluation of a novel zinc-based alloy stent in rabbit carotid artery model. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 107(6), 1814–1823. https://doi.org/10.1002/jbm.b.34274 [Google Scholar]
  • Dinc, R., & Ekingen, E. (2025). Biodegradable stents in the treatment of arterial stenosis. Journal of Clinical Medicine, 14(2), 532. https://doi.org/10.3390/jcm14020532 [Google Scholar]
  • REVA Medical. (n.d.). Fantom Encore: drug-eluting bioresorbable coronary scaffold. Retrieved from https://www.revamedical.com/why-bioresorbable-seaffolds/fantom-encore/ [Google Scholar]
  • van der Giessen, W. J., Slager, C. J., van Beusekom, H. M. M., van Ingen Schenau, D. S., Huijts, R. A., Schuurbiers, J. C., de Klein, W. J., Serruys, P. W., & Verdouw, P. D. (1992). Development of a polymer endovascular prosthesis and its implantation in porcine arteries: A polyethylene-terephthalate braided mesh stent developed by Akzo Research Laboratories and Akzo Fibres B.V. Journal of Vascular Medicine and Surgery, 1(2), 123–130. [Google Scholar]
  • Durand, E., Lemitre, M., Couty, L., Sharkawi, T., Brasselet, C., Vert, M., & Lafont, A. (2012). Adjusting a polymer formulation for an optimal bioresorbable stent: a 6-month follow-up study. EuroIntervention, 8(2), 242–249. https://doi.org/10.4244/EIJV8I2A38 [Google Scholar]
  • Stone, G. W., Ellis, S. G., Cox, D. A., Hermiller, J., O’Shaughnessy, C., Mann, J. T., Turco, M., Caputo, R., Bergin, P., Greenberg, J., Popma, J. J., & Russell, M. E. (2004). A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. New England Journal of Medicine, 350(3), 221–231. https://doi.org/10.1056/NEJMoa032441 [Google Scholar]
  • Oosterbeek, R. N., Zhang, X. C., Best, S. M., & Cameron, R. E. (2021). The evolution of the structure and mechanical properties of fully bioresorbable polymer-glass composites during degradation (arXiv preprint arXiv:2112.07326). https://doi.org/10.48550/arXiv.2112.07326 [Google Scholar]

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.