Issue |
BIO Web Conf.
Volume 33, 2021
The 1st International Conference of Advanced Veterinary Science and Technologies for Sustainable Development (ICAVESS 2021)
|
|
---|---|---|
Article Number | 02003 | |
Number of page(s) | 10 | |
Section | Bioengineering and Biotechnology | |
DOI | https://doi.org/10.1051/bioconf/20213302003 | |
Published online | 23 August 2021 |
The Development and Optimization of Primer Sets Used to Study the Relative Expression of Androgen Receptor Gene in Turkey (Meleagris gallopavo)
1
Research Center for Biology, Indonesian Institute of Sciences (LIPI), Jl. Jakarta-Bogor km 46, Cibinong, West Java, Indonesia 16911.
2
Department of Biochemistry, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Jl. Fauna 02, Caturtunggal, Depok, Sleman, Yogyakarta, Indonesia 55281
3
Department of Anatomy, Faculty of Veterinary Medicine, Universitas Gadjah Mada, Jl. Fauna 02, Caturtunggal, Depok, Sleman, Yogyakarta, Indonesia 55281
* Corresponding author: herj001@gmail.com
The Androgen Receptor (AR) Gene’s expression is essential during puberty and testes maturation, which is also used as a reference for Turkey’s breeding program. Therefore, this study aims to develop and optimize two primer sets for studying relative expression using qPCR technology. The primers were designed to amplify specific regions in the AR gene as the main target, and the β-actin gene as an internal control. They were tested using in-silico and amplicon sequencing, as well as efficiency calculation with a constructed standard curve from serially diluted reactions. Based on the sequencing methods, the primers amplified the corresponding regions of the respective targets. The primer for AR gene had an efficiency of 98.03%, a slope of -3.37, and an R2 of 0.995, while that of the β-actin gene had an efficiency of 98.01%, a slope of -3.371, and an R2 of 0.999. The two efficiencies exceeded the standard (93 -103%) value and the melting curve analysis showed that no non-specific amplification was discovered for both primers. According to the tests, the primers are suggested as acceptable to be used for the relative expression study of the AR gene in Turkey.
Key words: Androgen Receptor Gene / Primer / optimization / Turkey
© The Authors, published by EDP Sciences, 2021
This is an Open Access article distributed under the terms of the Creative Commons Attribution License 4.0, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
1 Introduction
Turkey has become a potential protein source popularly used in the USA and some European countries based on the higher protein and lower fat content compared to chicken [1, 2]. Meanwhile in Indonesia, it is not optimally used as a protein source because of the high price and breeders’ scarcity, and the meat is less consumed. Oktaviana et al. [2] analyzed turkey farming agribusiness management in Lampung Province and discovered that it was profitable.
Reproduction and the need for good quality turkey, as broodstock are important aspects of the breeding program. Furthermore, several parameters were used for gobblers (adult male turkey) and jakes (yearling male turkey) selection, for instance, androgen hormones and its receptor’s ‘analysis [3]. AR gene’s mRNA expression can be used as information about the gene regulation related to reproduction performances [4, 5]. The AR primer is chosen since the Androgen only affects a target when it expresses enough receptors [6].
A relative expression study using quantitative PCR (qPCR) approaches requires specific primers which are a set of oligonucleotides that initiates amplification in the polymerase chain reaction. The primers need to be designed based on several considerable requirements, such as their length, primer pair’s length difference, GC content, PCR product size, melting temperature, etc. [7]. Androgen receptor studies have been performed in turkey by Kiezun et al. [4, 5] which developed primer sets based on Gallus gallus transcripts. Therefore this study aims to develop and optimize the primers for studying a relative expression on M.gallopavo AR gene mRNA based on the bird’s predicted transcripts.
2 Materials and method
2.1. Ethical Approval
Every procedure conducted on the living animals used was approved by the Faculty of Veterinary Medicine, Universitas Gadjah Mada Ethical Clearance Committee, with document number: 0109/EC-FKH/Int./2019.
2.2. Primer Design and In-Silico Test
The primer sets were designed using Primer3Plus (http://bioinfo.ut.ee/primer3-0.4.0/), to amplify some areas in Meleagris gallopavo transcriptomes. AR gene’s primer was given code AR which was designed to amplify the partial area of DNA-binding domain to Ligand-binding domain, from nucleotide number 167 to 393 of the gene’s mRNA (Genbank: XM_031554642.1). β-actin gene’s primer was given code BAK, which was designed to amplify the partial area in the gene’s mRNA from nucleotide number 737 to 897 (Genbank: NM_001303179.1). The β-actin gene was chosen as internal control as it was also used by Kiezun, et.al [4, 5]. The primers were designed according to Chuang, et.al. [7] and they were then submitted for an in-silico test for primer specificity using Primer-BLAST (https://www.ncbi.nlm.nih.gov/tools/primer-blast). Their sequences can be seen in Table 1.
2.3. Nucleic Acid Template Preparation
The mRNA templates used were extracted from jakes’ fresh testicle tissues (n = 2) collected from a slaughterhouse in Bantul Regency, Yogyakarta. The testicles were preserved in RNALaterTM (ThermoFisher, USA) under -20°C condition. Total RNA was extracted from each sample using Total RNA Mini Kit (Tissue) (Geneaid®, Taiwan). Its quality and quantity were examined using microplate reader Infinite® 200 PRO NanoQuant (Tecan, Switzerland) and agarose gel electrophoresis respectively. About 1μg of the Total RNA was used as a template to synthesize cDNA using ReverTra Ace -ɑ-with gDNA remover (Toyobo, Japan). The genomic DNA needs to be digested before cDNA synthesis since it potentially alters amplification reaction, leading to unspecific amplicons.
Primer sequences
2.4. Primer Specificity Test
To clarify the primer sets’ ability to amplify the target, the PCR products/amplicons from each primer set were submitted for sequencing. The conventional polymerase chain reaction was performed on two samples using a thermal cycler (Infinigen Biotech. Inc, USA). This was performed for both primer sets in 35 cycles of denaturation at 94°C for 30 seconds, annealing at 58°C for 30 seconds, and elongation at 72°C for 30 seconds. Furthermore, the amplicons were submitted to First Base Laboratory (Selangor, Malaysia) for Sanger Sequencing. The sequences produced were then aligned with reference sequences in Genbank by using Nucleotide BLAST (https://blast.ncbi.nlm.nih.gov/).
2.5. Serial Dilution for Primers and cDNA Templates
Serial dilution was performed on both primer sets and cDNA templates in three levels, using RNase/DNase-free water. The primers were diluted into three levels of concentration, namely 0.4μM, 0.2μM, and 0.1μM. The Templates were also diluted 1x (10ng), 4x (2.5ng) and 10x (1ng).
2.6. qPCR Reaction and Data Analysis
Amplification for the qPCR reaction was performed using SYBRGreen® (Invitrogen, USA) as general fluorescence dye in AriaMx Real-Time PCR System (Agilent, USA). The PCR was conducted on 40 cycles of denaturation at 94°C for 30 seconds, annealing at 58°C for 30 seconds and lastly, elongation at 72°C for 30 seconds during which quantification data were collected. This amplification reaction was ended with a melting curve analysis at 65°C for 30 seconds. Threshold, primer efficiency, R2, slope and intercept values were set and calculated automatically using AriaMX’s software.
3 Result and Discussion
3.1. Primer Test
The in-silico test performed using PrimerBLAST showed the AR and BAK primers annealed to the corresponding targets in Meleagris gallopavo AR gene (Genbank: XM_031554642.1) and β-actin gene (Genbank: NM_001303179.1) respectively. The AR primer set was also annealed to the AR gene of Gallus gallus (Genbank: NM_001040090.1). Since the two birds are genetically related, the sequences are probably conserved as stated by Katoh, et al. [8]. The AR primers used in this study were designed to amplify the partial area in M.gallopavo predicted AR transcripts. Meanwhile, Kiezun et al. [4] designed their primer based on Gallus gallus AR mRNA (Genbank: NM_001040090).
The PCR products/amplicons from 2 samples were run on 1.2% agarose gel electrophoresis and distinct bands were shown for each primer, as can be seen in Figure 1. These were about 200-300bp and 100-200bp for AR and BAK primers respectively. According to NucleotideBLAST, the sequences obtained from sequencing also had high similarity with M. gallopavo AR and β-Actin genes (Table 2). The BAK primer amplicons had 100% sequence similarity with the reference sequence (Genbank: NM_001303173), meanwhile, that of the AR primer had 98.34-100% similarity (Genbank: XM_031554642.1).
![]() |
Fig 1. Gel electrophoresis for amplicons obtained using AR primer (1 & 3) and BAK primer (2 & 4). Distinct bands were observed in appropriate sizes for each amplicon as well as unspecific bands. |
NucleotideBLAST on amplicons from both primer sets
3.2. Primer Concentration Optimization
Three different concentrations of primer sets, namely 0.4µM, 0.2 µM, and 0.1 µM were used in the qPCR reaction. Non-template control (NTC) was also included in the reaction as a negative control. Primer sets with concentrations of 0.4µM and 0.2 µM produced close CT values compared to 0.1 µM, as can be seen in Figure 2 and Table 3. The CT values obtained during the concentration optimization ranged from 22.85 to 27.23 for AR primer and 15.89 to 20.83 for BAK primer.
Melting curve analysis showed a single peak for each sample, which indicated the qPCR reaction produced a specific single band only. The melting temperature for AR and BAK primers’ PCR products were around 82.5-83°C and 88°C respectively. Also, the melting curve and Tm value can be seen in Figure 3 and Table 3 respectively. The same and close Tm value indicates the PCR products have similar sequences that tend to melt in the same temperatures [9]. The NTC samples had a CT value recorded as 40.2, and a Tm value of 74. Since they had no added template, the amplification process occurred probably from primer dimer (PD) formation. This was proven in the melting curve analysis by having different Tm values with the test samples. Bustin et al. [10] stated that any CT value >40 generally need not be reported.
According to the reaction, the primer with a concentration of 0.1 µM had the best result as indicated by the CT value. Furthermore, the CT values produced were around 20.83 and 27.23 for AR and BAK primers respectively. Kuang et al. [9] stated CT values used for a relative expression study need to be around 20-30.
![]() |
Fig 2. Optimization of AR and BAK primers using a serial dilution, namely 0.4µM, 0.2 µM and 0.1 µM. The primer with 0.4µM and 0.2 µM concentrations produced a closer CT value compared to 0.1 µM. |
![]() |
Fig 3. Melting curve analysis on primer optimization reaction. The curve showed a single peak for each reaction indicating the qPCR reaction produced a specific single amplicon. |
CT and Tm values for each sample
3.3. AR Primer Reaction on Serially Diluted Template
The primer set was attempted to amplify three levels of serial dilution, 1/1, 1/3, and 1/9, aimed at efficiency calculation. In addition, the dilution and CT value were directly proportional as higher dilution caused the template concentration to become lower. The amplification curve and CT value can be seen in Figure 4 and Table 4. Melting curve analysis was also performed to clarify that the amplification produces a specific amplicon. The melting temperature on three levels of serial dilution showed the same Tm value, indicating the dilutions’ amplifications were structurally similar. The melting curve and Tm values were are presented in Figure 5 and Table 4 respectively.
A standard curve was constructed to calculate the primer efficiency and can be seen in Figure 6. It produced an efficiency of 98.03%, a slope of -3.37, and an R2 of 0.995. Kuang et.al. [9], recommend that the acceptable primer needs to have an efficiency of 93%-103%, a slope of -3.2 to -3.5, and an R2 of more than 0.98. However, the AR primer set used exceeded the recommended one.
![]() |
Fig 4. The curve obtained from qPCR with AR primer and serially diluted templates. The dilutions were 1/1, 1/3, and 1/9, with an initial concentration of 10ng/μl. The lower concentration tended to produce a higher CT value. |
![]() |
Fig 5. Melting curve analysis on qPCR with AR primer and serially diluted templates. The reaction’s curve showed an almost similar single peak, indicating that all the serially diluted templates produced a similar specific amplicon. |
Calculation of CT and Tm values for qPCR with AR primer and serially diluted templates
![]() |
Fig 6. The standard curve constructed from qPCR reaction with AR Primer and serially diluted templates. It produced an efficiency of 98.03%, a slope of -3.37 and an R2 of 0.995. |
3.4. BAK Primer Reaction on Serially Diluted Template
Primer efficiency test was also performed on BAK Primer. Furthermore, the reaction was conducted on three levels of serial dilution, 1/1, 1/3, and 1/9, with an initial concentration of 10ng/μl. This produced a similar pattern with AR primer, where higher dilution produced higher CT value, while the amplification curve can be seen in Figure 7.
The melting curve analysis on three levels of serial dilution templates also produced a single peak. This indicated that the amplicons from the serially diluted samples were structurally similar as they melt at the same temperature. The result of the analysis is presented in Figure 8.
A standard curve was also constructed to calculate BAK primer efficiency. It produced an efficiency of 98.01, a slope of -3.371, and an R2 of 0.999 as can be seen in Figure 9. The BAK primer also exceeded the minimal recommendation stated by Kuang et al. [9].
The AR and BAK primer sets designed in this research amplified the AR and β-Actin genes, respectively. These were specific to anneal on the target sequences as proven by in-silico and amplicon sequencing followed by nucleotide BLAST. They also annealed on closely related organisms as shown in G. gallus gene by the in-silicon method. The amplification reaction conducted using both primers produced a specific amplicon as shown by the melting curve analysis. This occurred in NTC samples after the 40th cycle and can be eliminated from the analysis [10]. The two above-mentioned sets exceeded the minimum primer efficiency parameters stated by Kuang et al [9].
![]() |
Fig 7. The curve obtained from qPCR with BAK primer and serially diluted templates. The dilutions were 1/1, 1/3, and 1/9, with an initial concentration of 100μg/μl. The lower concentration tended to produce a higher CT value. |
![]() |
Fig 8. The melting curve analysis on qPCR with BAK primer and serially diluted templates. The reaction’s curve showed a similar single peak, which indicated all the serially diluted templates produced similar specific amplicon. |
![]() |
Fig 9. A standard curve constructed from qPCR reaction with BAK Primer and serially diluted templates. It produced an efficiency of 98.01, a slope of -3.371, and an R2 of 0.999. |
4 Conclusion
The primer sets developed exceeded the minimum requirement. They need to be tested on many samples and in different age groups to distinguish genes’ expression.
The authors are grateful to Universitas Gadjah Mada for funding this study through the 2018 RTA Program.
References
- A. Bordoni, F. Danesi. (Elsevier Ltd., 2017). [Google Scholar]
- E. Oktaviana, D.A.H. Lestari, Y. Indriani. JIIA. 4, 3 (2016) [Google Scholar]
- R.A. Dornas, A.G. Oliviera, M.O. Dias, G.A. Mahecha, C.A. Oliviera. Gen.Comp.Endocrinol. 166 (2008). [Google Scholar]
- J. Kiezun, A. Leska, B. Kaminska, J. Jankowski, L. Dusza. Gen. Comp. Endocrinol. 214 (2015) [Google Scholar]
- J. Kiezun, B. Kaminska, J. Jankowski, L. Dusza. Gen. Comp. Endocrinol, 217–218 (2015) [Google Scholar]
- R.A. Davey, M. Grossmann Clin Biochem Rev. 37, 1 (2016) [Google Scholar]
- L.Y. Chuang, Y.H. Cheng, C.H. Yang, S. Biotechnol Lett., 35, 10 (2013) [Google Scholar]
- H. Katoh, Y. Ogino, G. Yamada, FEBS Letter. 580, 6 (2006) [Google Scholar]
- J. Kuang, X. Yan, A.J. Genders, C. Granata, D.J. Bishop, Plos One 13, 5 (2018) [Google Scholar]
- S.A. Bustin, V. Benes, J.A. Garson, J. Hellemans, J. Huggett, M. Kubista, R. Mueller, T. Nolan, M.W. Pfaffl, G.L. Shipley, J. Vandesompele, C.T. Wittwer. Clin.Chem 55, 4 (2009) [Google Scholar]
All Tables
Calculation of CT and Tm values for qPCR with AR primer and serially diluted templates
All Figures
![]() |
Fig 1. Gel electrophoresis for amplicons obtained using AR primer (1 & 3) and BAK primer (2 & 4). Distinct bands were observed in appropriate sizes for each amplicon as well as unspecific bands. |
In the text |
![]() |
Fig 2. Optimization of AR and BAK primers using a serial dilution, namely 0.4µM, 0.2 µM and 0.1 µM. The primer with 0.4µM and 0.2 µM concentrations produced a closer CT value compared to 0.1 µM. |
In the text |
![]() |
Fig 3. Melting curve analysis on primer optimization reaction. The curve showed a single peak for each reaction indicating the qPCR reaction produced a specific single amplicon. |
In the text |
![]() |
Fig 4. The curve obtained from qPCR with AR primer and serially diluted templates. The dilutions were 1/1, 1/3, and 1/9, with an initial concentration of 10ng/μl. The lower concentration tended to produce a higher CT value. |
In the text |
![]() |
Fig 5. Melting curve analysis on qPCR with AR primer and serially diluted templates. The reaction’s curve showed an almost similar single peak, indicating that all the serially diluted templates produced a similar specific amplicon. |
In the text |
![]() |
Fig 6. The standard curve constructed from qPCR reaction with AR Primer and serially diluted templates. It produced an efficiency of 98.03%, a slope of -3.37 and an R2 of 0.995. |
In the text |
![]() |
Fig 7. The curve obtained from qPCR with BAK primer and serially diluted templates. The dilutions were 1/1, 1/3, and 1/9, with an initial concentration of 100μg/μl. The lower concentration tended to produce a higher CT value. |
In the text |
![]() |
Fig 8. The melting curve analysis on qPCR with BAK primer and serially diluted templates. The reaction’s curve showed a similar single peak, which indicated all the serially diluted templates produced similar specific amplicon. |
In the text |
![]() |
Fig 9. A standard curve constructed from qPCR reaction with BAK Primer and serially diluted templates. It produced an efficiency of 98.01, a slope of -3.371, and an R2 of 0.999. |
In the text |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.